Pushbutton Switches / Indicators
last update: February 7, 2014
| UL, cUL | UL 508/CSA C22.2 No.14
File No. E76675 6A 240VAC/10A 120VAC |
|---|---|
| EN | EN60947-5-1 (low voltage directive) 3A 240VAC (AC-15) |
| CCC | GB/14048.5-2001
3A 240VAC/1.5A 24VDC |
| UL, cUL | UL 508/CSA C22.2 No.14
File No. E76675 24VAC/DC MAX |
|---|
| UL, cUL | UL 508/CSA C22.2 No.14
File No. E76675 220VAC |
|---|---|
| CCC | GB/14048.5-2001
220VAC |
| UL, cUL | UL 508/CSA C22.2 No.14
File No. E76675 12A: 12VAC/DC 24A: 24VAC/DC T2: 220VAC |
|---|---|
| CCC | GB/14048.5-2001
T2: 220VAC |
| Rated current
(A) |
Rated voltage
(V) |
Inductive load | |
|---|---|---|---|
| Rated current (A) | Power facfor | ||
| 10 | 240 | 3 | 0.4 |
Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the following conditions:
Ambient temperature: 20+/- 2ºC
Ambient humidity: 65+/-5%RH
Operating frequency: 30 operations/minute
| Operating voltage | Current consumption |
|---|---|
| AC/DC 6V±5% | 20mA |
| AC/DC 12V±5% | 20mA |
| AC/DC 24V±5% | 20mA |
| Operating voltage | Current consumption |
|---|---|
| AC/DC 12V±5% | 20mA |
| AC/DC 24V±5% | 20mA |
| Operating voltage | Current consumption |
|---|---|
| AC 200V(190 to 230V) | 20mA |
| Ambient temperature*1 | Non-lighted type: -20 to +60ºC
Lighted type: -20 to +50ºC |
|---|---|
| Ambient humidity | -35 to 85%RH |
| Storage temperature*1 | -40 to +70ºC |
| Protective code*2 | IP65 |
| Vibration resistance | 10 to 55Hz, Double amplitude 1.5mm |
| Shock resistance | Non-lighted type: 1,000m/s2
Lighted type: 600m/s2 |
*1: With no icing or condensation
*2: Protection against dust or water from the front of a mounting panel side
| Operation | Slow action | |
|---|---|---|
| Operating
frequency |
Mechanical | Momentary operation: 60 operations/minute max. |
| Electrical | Knob-type and Key-type selector: 30 operations/minute max. | |
| Mechanical durability | Momentary switch:3,000,000 operations
Alternate, Key/Knob Selector switches: 300,000 operations |
|
| Insulation resistance | 100MΩ Minimum (At 500VDC) |
|---|---|
| Dielectric strength | Between terminals of same polarity: AC2,500V 50/60Hz for 1 minute
Between terminals of different polarity: AC2,500V 50/60Hz for 1 minute |
| Rating | AC-15, A600, Ue=240V, Ie=3A |
| Rated insulation voltage | Ui=600V, Pollution degree: 3 |
| Conditional short-circuit current | 10A, IEC60209-1 |
| Electrical durability | 500,000 operations Minimum (at AC 240V, 3A, cosø=0.4) |
| Total Travel Force (TTF) | 29.4N Maximum |
|---|---|
| Total Travel (TT) | 5.5mm Maximum |
| Total Travel Force (TTF) | Manual reset: 0.34N·m Maximum *
Auto-reset 2-notch: 0.25N·m * 3-notch: 0.34N·m * |
|---|---|
| Total Travel (TT) | 2-notch: approx. 90 degree (3-notch: approx.45 degree) |
| Releasing Force (RF) | Manual reset: 0.34N·m Maximum * |
* Rotation torque for knob type/key type selector switches.
| Total Travel Force (TTF) | Manual reset: 0.34N·m Maximum *
Auto-reset 2-notch: 0.25N·m * 3-notch: 0.34N·m * |
|---|---|
| Total Travel (TT) | 2-notch: approx. 90 degree (3-notch: approx.45 degree) |
| Releasing Force (RF) | Manual reset: 0.34N·m Maximum * |
* Rotation torque for knob type/key type selector switches.
last update: February 7, 2014