Terminal Relay
last update: May 20, 2024
Operation
coil rating |
Rated current
(mA) |
Coil resistance
(Ω) |
Must operate
voltage (V) |
Must release
voltage (V) |
Max.
voltage (V) |
Power
consumption (mW) |
|
---|---|---|---|---|---|---|---|
DC | 12 | 18.7 | 720 | 70%
max.* |
10%
min. |
130% | Approx. 200 |
24 | 10.5 | 2,880 |
Note:
1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±20%.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the operating voltage for the relay coil operating power supply. There is no continuous allowance.
4. The rated current includes the terminal’s LED current.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted in the upside down.
Load | Resistive load (cosφ = 1) |
---|---|
Rated load | 5 A at 250 VAC, 5 A at 30 VDC |
Rated carry current | 5 A |
Max. switching voltage | 250 VAC, 30 VDC |
Max. switching current | 5 A |
Max. switching capacity (reference value) | 1,250 VA, 150 W |
Load | Resistive load (cosφ = 1) |
---|---|
Rated load | 3 A at 250 VAC, 3 A at 30 VDC |
Rated carry current * | 5 A |
Max. switching voltage | 250 VAC, 30 VDC |
Max. switching current * | 5 A |
Max. switching capacity (reference value) * | 1,250 VA, 150 W |
* The specifications become 3 A, 750 VA, and 90 W when all four outputs are powered at the same time.
Model | G6D-F4PU
(Model with Push-In Plus technology) |
|
---|---|---|
Relay output | ||
Contact resistance *1 | 100 mΩ max. | |
Operate time *2 | 10 ms max. | |
Release time *2 | 10 ms max. | |
Insulation resistance | 1,000 MΩ min. (at 500 VDC) | |
Dielectric
strength |
Between coil and
contacts |
2,000 VAC, 50/60 Hz for 1 min |
Between contacts
of the same polarity |
750 VAC, 50/60 Hz for 1 min | |
Shock resistance voltage
(between coil and contacts) |
4,000 V (1.2 × 50 μs) | |
Vibration re-
sistance |
Destruction | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
|
Shock
resistance |
Destruction | 500 m/s2 |
Malfunction | 100 m/s2 | |
Endurance | Mechanical | 20,000,000 operations min.
(switching frequency: 18,000 operations/hr) |
Electrical *2 | 70,000 operations min.
(5 A at 250 VAC, resistive load) 70,000 operations min. (5 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) |
|
Failure rate P Level
(reference value *3) |
10 mA at 5 VDC | |
Ambient operating temperature,
Ambient storage temperature |
-25 to 55°C (with no icing) | |
Ambient operating humidity | 45% to 85% | |
LED color | Yellow | |
Sealing | IP20 | |
Weight | Approx. 86 g |
Note: The data shown above are initial values.
*1. Measurement condition: 1 A at 5 VDC
*2. Ambient temperature condition: 23°C
*3. This value is measured at 120 switching frequencies/min.
Model | G6D-F4B
(Model with Screw terminal) |
|
---|---|---|
Relay output | ||
Contact resistance *1 | 100 mΩ max. | |
Operate time *2 | 10 ms max. | |
Release time *2 | 10 ms max. | |
Insulation resistance | 1,000 MΩ min. (at 500 VDC) | |
Dielectric
strength |
Between coil and
contacts |
2,000 VAC, 50/60 Hz for 1 min |
Between contacts
of the same polarity |
750 VAC, 50/60 Hz for 1 min | |
Shock resistance voltage
(between coil and contacts) |
4,000 V (1.2 × 50 μs) | |
Vibration re-
sistance |
Destruction | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
|
Shock
resistance |
Destruction | 500 m/s2 |
Malfunction | 100 m/s2 | |
Endurance | Mechanical | 20,000,000 operations min.
(switching frequency: 18,000 operations/hr) |
Electrical *2 | 200,000 operations min.
(3 A at 250 VAC, resistive load) 200,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 switching frequencies/hr) |
|
Failure rate P Level
(reference value *3) |
10 mA at 5 VDC | |
Ambient operating temperature,
Ambient storage temperature |
-25 to 55°C (with no icing) | |
Ambient operating humidity | 45% to 85% | |
LED color | Yellow | |
Sealing | --- | |
Weight | Approx. 65 g |
Note: The data shown above are initial values.
*1. Measurement condition: 1 A at 5 VDC
*2. Ambient temperature condition: 23°C
*3. This value is measured at 120 switching frequencies/min.
Rated
voltage |
Operating
voltage |
Must operate
voltage level |
Must release
voltage level |
Input
impedance |
Rated
current |
|
---|---|---|---|---|---|---|
DC | 12 | 9.6 to 14.4 VDC | 9.6 VDC max. | 1 VDC min. | 2 kΩ ±20% | 8.0 mA ±20% |
24 | 19.2 to 28.8 VDC | 19.2 VDC max. | 4 kΩ ±20% | 8.2 mA ±20% |
Note: The rated current includes the terminal’s LED current.
Rated operating
voltage |
Load voltage
range |
Load current | Inrush current
resistance |
---|---|---|---|
5 to 240 VAC
5 to 100 VDC |
3 to 264 VAC
3 to 125 VDC |
100 μ to 0.3 A | 6 A (10 ms) |
Note: There is no output polarity for the G3DZ.
Model | G3DZ-F4PU
(Model with Push-In Plus technology) |
---|---|
Power MOS FET relay output | |
Must operate time | 10 ms max. |
Release time | 15 ms max. |
Output ON-resistance | 2.4 Ω max. |
Leakage current at OFF state | 10 μA max. (at 125 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength between I/O | 2,000 VAC, 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
Shock resistance | 500 m/s2 |
Ambient operating temperature,
Ambient storage temperature |
-25 to 55°C (with no icing) |
Ambient operating humidity | 45% to 85% |
LED color | Yellow |
Sealing | IP20 |
Weight | Approx. 86 g |
Model | G3DZ-F4B
(Model with Screw terminal) |
---|---|
Power MOS FET relay output | |
Must operate time | 10 ms max. |
Release time | 15 ms max. |
Output ON-resistance | 2.4 Ω max. |
Leakage current at OFF state | 10 μA max. (at 125 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength between I/O | 2,000 VAC, 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) |
Shock resistance | 500 m/s2 |
Ambient operating temperature,
Ambient storage temperature |
-25 to 55°C (with no icing) |
Ambient operating humidity | 45% to 85% |
LED color | Yellow |
Sealing | --- |
Weight | Approx. 65 g |
The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use.
Model | Standard
number |
Category | Listed/
Recognized Classification |
Operating
coil ratings |
Number
of poles |
Contact ratings | Operations |
---|---|---|---|---|---|---|---|
G6D-F4PU | UL508 | NRNT/7 | Listed | 12 VDC
24 VDC |
4 | Rated load voltage
250 VAC 30 VDC Load Current, General Use and Resistive 5 A |
6,000
operations. |
G3DZ-F4PU | Rated load voltage
5-240 VAC 5-100 VDC Load Current, General Use and Resistive 0.3 A |
--- | |||||
P6DF-F4PU | SWIV2 | Recognized | 5 A, 250 V | --- |
Model | Standard number | Class number | Operating
coil ratings |
Number
of poles |
Contact ratings | Operations |
---|---|---|---|---|---|---|
P6DF-F4PU | C22.2 NO. 14 | CLASS 3211 07 | 12 VDC
24 VDC |
4 | 5 A, 250 V | --- |
Model | Operating Coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
G6D-F4PU | 12 VDC
24 VDC |
4 | AC250 V, 5 A (Res.)
DC30 V, 5 A (Res.) |
70,000 operations
70,000 operations |
Model | Operating Coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
G3DZ-F4PU | 12 VDC
24 VDC |
4 | AC5-240 V, 5 A (Res.)
DC5-100 V, 5 A (Res.) |
--- |
Model | Operating Coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
P6DF-F4PU | 12 VDC
24 VDC |
4 | AC250 V, 5 A
DC100 V, 5 A |
--- |
Model | Standard
number |
Category | Listed/
Recognized Classification |
Operating
coil ratings |
Number
of poles |
Contact ratings | Operations |
---|---|---|---|---|---|---|---|
G6D-F4B | UL508 | SWIV2 | Recognized | 12 VDC
24 VDC |
4 | Rated load voltage
250 VAC 30 VDC Load Current 5 A, Resistive |
6,000 operations. |
G3DZ-F4B | Rated load voltage
3-264 VAC 3-125 VDC Load Current 0.3 A |
--- |
Model | Standard
number |
Class number | Operating
coil ratings |
Number
of poles |
Contact ratings | Operations |
---|---|---|---|---|---|---|
G6D-F4B | C22.2 NO. 14 | CLASS 3211 07 | 12 VDC
24 VDC |
4 | Rated load voltage
250 VAC 30 VDC Load Current 5 A, Resistive |
--- |
G3DZ-F4B | Rated load voltage
3-264 VAC 3-125 VDC Load Current 0.3 A, Resistive |
--- |
Model | Operating coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
G6D-F4B | 12 VDC
24 VDC |
4 | 250 VAC, 3 A
24 VDC, 3 A |
--- |
Model | Operating coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
G3DZ-F4B | 12 VDC
24 VDC |
4 | 5-240 VAC, 0.3 A
5-100 VDC, 0.3 A |
--- |
Model | Operating coil ratings | Number of poles | Contact ratings | Operations |
---|---|---|---|---|
P6DF-F4B | 12 VDC
24 VDC |
4 | 250 VAC, 0.3 A | --- |
last update: May 20, 2024